It is currently Sun 24. Nov 2024 3:39:59
|
View unanswered posts | View active topics
Author |
Message |
Manfred
|
Posted: Sun 31. Jan 2021 19:54:51 |
|
Joined: Tue 14. Jul 2020 13:10:08 Posts: 18
|
Hello,
updated my Radio DS 16 and Spirit RS to 3.2.2.
If i use now the device explorer to RS the screen jumps allways back after a couple of seconds to the device explorer.
What is wrong ?
Best Manfred
|
|
Top |
|
|
ZeXx86
|
Posted: Sun 31. Jan 2021 20:13:57 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
Hello,
can you check if serial number of the unit ends with -a1 in the Connection tab, Spirit Settings? Also have you updated BIN file in the Devices directory (radio)?
_________________ Spirit System developer
|
|
Top |
|
|
Manfred
|
Posted: Sun 31. Jan 2021 20:29:51 |
|
Joined: Tue 14. Jul 2020 13:10:08 Posts: 18
|
Hi,
Yes to both. Serial ends with.... 55-a1 Updated Spirit.bin to newest Version.
Best Manfred
|
|
Top |
|
|
ZeXx86
|
Posted: Sun 31. Jan 2021 20:33:28 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
Great. Is something connected in the E2 port of the Spirit RS unit? It seems connection is somehow unstable. By connecting something in the E2 it can cause such troubles, because E2 is used for data transmission in normal configuration.
_________________ Spirit System developer
|
|
Top |
|
|
Manfred
|
Posted: Sun 31. Jan 2021 20:38:11 |
|
Joined: Tue 14. Jul 2020 13:10:08 Posts: 18
|
Hi,
no, E1 and E2 are not in use.
Best
|
|
Top |
|
|
ZeXx86
|
Posted: Sun 31. Jan 2021 20:41:05 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
Thank you. Could you please share your settings? Preferably 4ds file. Tomorrow we can verify behavior with the settings and let you know. I believe it can be resolved easily. But we never encountered such behavior.
_________________ Spirit System developer
|
|
Top |
|
|
Manfred
|
Posted: Sun 31. Jan 2021 20:46:53 |
|
Joined: Tue 14. Jul 2020 13:10:08 Posts: 18
|
many Thx.
Here you are.
Manfred
Attachments: |
G380.4ds [255 Bytes]
Downloaded 120 times
|
|
|
Top |
|
|
ZeXx86
|
Posted: Mon 01. Feb 2021 8:24:35 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
Thank you. We have not found anything strange in the settings. It is working perfectly with our untis.
Maybe you have opened Spirit Settings at the same time as the integration? If you will access Spectrum Analysis there then it will close the integration. This is correct behavior.
_________________ Spirit System developer
|
|
Top |
|
|
Manfred
|
Posted: Mon 01. Feb 2021 19:28:16 |
|
Joined: Tue 14. Jul 2020 13:10:08 Posts: 18
|
Hi, no, no use of connection on same time.
Before Update everything is working fine,
Attached a short movie, how the failure looks.
Sorry, file seems to large for appendix. Can I send it to another email?
Best Manfred
|
|
Top |
|
|
ZeXx86
|
Posted: Mon 01. Feb 2021 21:45:21 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
Hi, you can upload the file here for example: https://ufile.io/
_________________ Spirit System developer
|
|
Top |
|
|
|
Who is online |
|
Users browsing this forum: No registered users and 61 guests |
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot post attachments in this forum
|