Alyon187
|
Posted: Fri 18. Aug 2017 13:36:32 |
|
Joined: Sat 14. Nov 2015 8:08:20 Posts: 131
|
Are this two connectors the same? Or is there some internal wiring thats different? So can i use the spektrum adaptor that i already have and use it for the HW telemtry cable?
|
|
Top |
|
|
ZeXx86
|
Posted: Fri 18. Aug 2017 13:39:28 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
They are not same.
You can make Telem UNI from Spektrum adapter by unplugging/cutting red wires (ideally from both connectors). Then it will work. Without this modification it can cause a big problems.
_________________ Spirit System developer
|
|
Top |
|
|
Alyon187
|
Posted: Fri 18. Aug 2017 21:44:30 |
|
Joined: Sat 14. Nov 2015 8:08:20 Posts: 131
|
So just disconnect the red wires from both ends of the sat adaptor?
|
|
Top |
|
|
ZeXx86
|
Posted: Fri 18. Aug 2017 22:01:54 |
|
|
Site Admin |
Joined: Mon 29. Apr 2013 16:06:44 Posts: 12442
|
yes
_________________ Spirit System developer
|
|
Top |
|
|
simplechamp
|
Posted: Sat 19. Aug 2017 16:15:49 |
|
Joined: Tue 08. Dec 2015 17:48:45 Posts: 12
|
I made my own this way. Used my crimp tool to crimp regular servo pins onto one end of the sat cable. The unused + wire was folded back and covered with heatshrink.
If using orange-black-grey sat cable the orange is + and needs to be removed. Grey is signal and black is -
|
|