Hi,

with Spirit version 2.41 I have started to use the telemetrie with a CC Edge 80 HV on my Jeti DS-14. My observation is, that several values of the capacity are missing. That might explain the ratio from 0.77 to 1.03 in different flights between the charged an the displayed values. The other values e.g. current, voltage seem to be fine. Is that a problem of the CC Edge or from the current Spirit firmware?

Gesendet von meinem Lenovo TAB 2 A10-70F mit Tapatalk


Top
 Profile  
 
PostPosted: Sun 04. Jun 2017 10:48:26 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Hi,

I am not sure if I understand the problem correctly.
Is the problem that you can see different values between each flight?
Or that you are loosing some data from the flight? If you are loosing some data, please check the log in your transmitter.
This can tell us when the issue occur and to which variables.

Capacity is based on the current measurement, so if there is no current value, then capacity will be calculated incorrectly.

Do you use our Telem CC cable?

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Sun 04. Jun 2017 11:08:54 
Offline

Joined: Sun 28. Dec 2014 22:39:47
Posts: 85
Yes, I use your Telem CC cable. I am analyzing the data in the log file. The values for current (approx. 900 values) are all ok. But for the capacity only approx. 140 values are there. If you replay the flights in the Jeti tool, often no values for the capacity are shown.
Another fact is, that the ratio between charged and displayed capacity differs from 0.77 to 1.11.

If it is usefull I can send you some logfiles.

http://cloud.tapatalk.com/s/593402f444a3f/17-36-07.log
http://cloud.tapatalk.com/s/5934030aa7fc6/18-54-42.log


Top
 Profile  
 
PostPosted: Wed 07. Jun 2017 8:41:08 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Hello,

thank you for the logs.

We have checked it and you are right that for capacity there are less values - but this is normal. It is same for the temperature.
This is because such variables have slower refresh rate, because they are not changing too much (not needed to see is that fast as for example current or voltage).
But the values are really wrong if you can see such difference between flights.

For this reason we are doing more tests between pilots.
We have updated firmware which we are testing right now.

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Wed 07. Jun 2017 20:21:40 
Offline

Joined: Sun 28. Dec 2014 22:39:47
Posts: 85
Hello,

thanks for your analysis. I also can do some more testing if you want.


Top
 Profile  
 
PostPosted: Fri 09. Jun 2017 20:37:00 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Hello,

thank you for your help!
I would like to only know, if you are using Governor from the ESC or unit?

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Sat 10. Jun 2017 11:51:25 
Offline

Joined: Sun 28. Dec 2014 22:39:47
Posts: 85
I'm using the governor from Spirit and not the one from ESC


Top
 Profile  
 
PostPosted: Sat 10. Jun 2017 11:55:26 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Do you think it would be possible to change for the ESC governor?
The problem with CC telemetry is that data are going over the same cable. When governor is enabled, unit is changing signal all the time and it is then hard to find valid signal between such data.
Maybe the problem is there - in any way we will try to find a solution as soon as possible.

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Sun 11. Jun 2017 7:42:07 
Offline

Joined: Sun 28. Dec 2014 22:39:47
Posts: 85
I can try that. But could that be the problem? As I know the capacity is derived from the current and the current seems to be fine - isn't it? Therefore it should more be an issue in calculating the capacity internally.


Top
 Profile  
 
PostPosted: Sun 11. Jun 2017 11:04:56 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
You are right, but in case that some data are not valid, they are skipped - in this case current value will be used from the previous valid frame. If there are more cases like this in row, then the capacity calculation is based rather only on portion of real values. This could lead to such imprecision and various ratio between charged and consumed capacity.

_________________
Spirit System developer


Top
 Profile  
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 20 posts ]  Go to page 1, 2  Next

All times are UTC + 1 hour


Who is online

Users browsing this forum: Amatrix and 8 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
cron



Powered by phpBB © 2000, 2002, 2005, 2007 phpBB Group
skymiles_red v1.0.1 designed by Team -Programming forum-سيارات للبيع .