It is currently Sat 23. Nov 2024 19:45:25

All times are UTC + 1 hour





Post new topic Reply to topic  [ 7 posts ] 
  Print view Previous topic | Next topic 
Author Message
PostPosted: Thu 30. Jun 2016 22:28:19 
Offline

Joined: Wed 22. Jul 2015 16:02:51
Posts: 98
Hi Serviceteam,
what will happen if Spirit's Failsafe Algorithmus has been already started. Will rescue function still useable / function ?
And is it possible to come back to regular processing if Failsafe has been started / executed ? If yes - how.
thanks in advance
br Siggi


Top
 Profile  
 
PostPosted: Thu 30. Jun 2016 22:34:55 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Hi,

when failsafe is engaged, channels values are set to these that were saved for this mode.
When signal from the transmitter is regained back, it will work again correctly and model is fully controlable (if signal is good). This is completely automatic.
Then if it is lost, the failsafe will be engaged again.

This will be also reported in the log from "the previous flight".

So failsafe can be activated/deactivated as many times as needed.

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Fri 01. Jul 2016 7:49:01 
Offline

Joined: Wed 22. Jul 2015 16:02:51
Posts: 98
Hi serviceteam that's fine :D ;
I read documentation about Failsafe in spirit fbl if SUMD connection is used failsafe could be set. Is it a must have or an option. I understand it as option.
I would like to set failsafe only at RX - expecting that every failsafe option a configured at RX a send as normal request to spirit FBL.
why ? Because there is only one place ro configure . Therfore is it possible to deactive failsafe settings in spirit fbl?
thanks in advance and br Siggi


Top
 Profile  
 
PostPosted: Fri 01. Jul 2016 9:00:55 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
Failsafe from the unit will be active only when receiver will stop sending any data. If it has own failsafe defined, it will be used. If no, failsafe from the unit will be used.
For example if connection between receiver and unit will fail, only unit can act thus failsafe is activated there.

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Fri 01. Jul 2016 10:11:05 
Offline

Joined: Wed 22. Jul 2015 16:02:51
Posts: 98
Hi Serviceteam,
okay - but I would like to deactivate FBL FailSafe Setting - no action there.
Is that possible ?
br Siggi


Top
 Profile  
 
PostPosted: Fri 01. Jul 2016 10:28:55 
Offline
Site Admin

Joined: Mon 29. Apr 2013 16:06:44
Posts: 12442
No, because there is no reason to deactivate it. It is safety feature.
If failsafe from the receiver will not react and failsafe from the unit too, then your helicopter can fly away uncontrollable.
Receiver failsafe has always bigger priority (if it is present) so there is no downside when second failsafe is in the unit too.
Both are completely independent and can't be activated at the same time.

_________________
Spirit System developer


Top
 Profile  
 
PostPosted: Fri 01. Jul 2016 11:27:25 
Offline

Joined: Wed 22. Jul 2015 16:02:51
Posts: 98
Hi Serviceteam,
your are right that make sense as long both configurations are organized in a proper way. Proper way - clear rules what will happen.
thanks and br
Siggi


Top
 Profile  
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 7 posts ] 

All times are UTC + 1 hour


Who is online

Users browsing this forum: Bing [Bot], mainstreet and 63 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  



Powered by phpBB © 2000, 2002, 2005, 2007 phpBB Group
skymiles_red v1.0.1 designed by Team -Programming forum-سيارات للبيع .