Gov with Bailout is a straight forward concept, all what's relevant is what you see on Spirit diagnostics.
Below 50% TC gets straight Forward to ESC.
Once above 50% Gov is engaged with requested rpm = max rpm * %
Now if you reduce now TC, but stay above 12% Bailout is activated, which means approximately spoolup in 1/3 of regular spoolup time.
If TC gets now below 12% next Spoolup is normal.
Try it with a Servos instead a ESC or with Y-Cable, you will see Servos move to monitor what's going to ESC.
As I use only Bailout during Auro Training, I use line 0% for Hold, Normal 75% Mode 1 90% and Mode2 100%.
I did add a Switch called Auro Training, which adds 15% but only on Hold.
Means no Bailout during normal operation, but if I do Auro for Training, I arm Bailout with the Switch.
It also depends on how you use your ESC and if there is a build in Bailout in ESC with it's own thresholds.
You might have a look on my Step by Step guide for CC Edge ESC based on combination of ESC bailout and Spirit Bailout together.
viewtopic.php?f=17&t=1364